What is a pillar fire hydrant? A pillar fire hydrant is one of the components on a fire hydrant that serves as a water point that can be accessed by the fire fighters to put out the fire.
Pillar hydrants are an important component in the fire protection system of buildings and industrial areas.
So, let’s get the full understanding of what is a pillar fire hydrant and alongside of its functions and components in today’s article, only at dimulti.id!
Also Read
Table of Contents
What is a Pillar Fire Hydrant?

As we stated before, a pillar fire hydrant is a device that serves as a water point that can be accessed by the fire to put out the fire.
The pillar hydrant is usually placed outside of a building that can be easily accessed by the fire fighter to quickly gain access to water.
Also, the pillar fire hydrant is connected to a water reservoir and equipped with a high-pressure water to be able to reach the fire point.
When the fire occurs, the fire fighter will open up the valve that is present in the pillar hydrant, and after the valve being opened, the fire hose can be connected to the pillar to be then directed to the fire.
Also Read: “How to Properly Use a Fire Extinguisher?“
Components of the Pillar Fire Hydrant

There are several components of the pillar hydrant that work in conjunction to ensure the maximum performance of the hydrant itself.
Knowing these components can help you to further understand and perform necessary maintenance to this device.
So, without further ado, let’s get going!
Also Read: “NFPA Fire Classification“
1. Main Pipe
The main pipe is the main channel that connects the hydrant pillar with the main water reservoirs, such as the ground tank of the fire extinguisher.
The piping system on the fire hydrant is made of materials that are corrosion- and pressure-resistant, like steel and iron.
2. Valve
The next one is the valve. The valve serves a function to control the water flow from the water reservoirs.
The valve can be opened or closed, and with this component, the fire fighter can control the flow of the water to be used to putting out the water
3. Hose Connection
As its name implies, the hose connection is the component of the pillar hydrant that serves as a place where the fire hose is connected to the valve.
Through this component, the fire fighter can connect the fire hose that it used to channel the water to be then directed to the fire points.
4. Caps
When the pillar hydrant is not being used, the valve can be closed to protect the hose connection from dust or dirt.
And the component that used to close it is the caps, this component is also important to ensure the cleanliness of the internal of the pillar hydrant.
The cleanliness of a hydrant is so important, as a dirty hydrant can cause the hose connection to rusted thus making it harder to connect the hose.
5. Body
The last one is the body of the pillar hydrant itself. This component serves as a housing to other components that we stated above.
It can help integrate all of the other components so it can function properly, and also keep the stability of the overall hydrant’s system.
There you go! The explanation of “what is a pillar hydrant” alongside its components!