{"id":1971,"date":"2024-08-14T06:39:52","date_gmt":"2024-08-14T06:39:52","guid":{"rendered":"https:\/\/www.dimulti.id\/SNI\/?p=1971"},"modified":"2024-10-27T11:58:31","modified_gmt":"2024-10-27T11:58:31","slug":"testing-procedures-of-sni-iec-66086-12015","status":"publish","type":"post","link":"https:\/\/www.dimulti.id\/SNI\/testing-procedures-of-sni-iec-66086-12015\/","title":{"rendered":"Testing Procedures of SNI IEC 66086-1:2015"},"content":{"rendered":"\n<p><strong>Testing Procedures of SNI IEC 66086-1:2015 &#8211; <\/strong>There are several things that must be done before the SNI certificate is issued for battery products in Indonesia.<\/p>\n\n\n\n<p>These procedures and steps must be taken to measure several aspects of the safety and quality of the battery.<\/p>\n\n\n\n<p>So, what are the testing procedures that must be done to ensure that each and every battery in Indonesia has good quality and qualified safety according to the SNI IEC 60086-1: 2015? Let&#8217;s see the full explanation below!<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title ez-toc-toggle\" style=\"cursor:pointer\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.dimulti.id\/SNI\/testing-procedures-of-sni-iec-66086-12015\/#Testing_Procedures_of_SNI_IEC_66086-1_2015\" >Testing Procedures of SNI IEC 66086-1:2015<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.dimulti.id\/SNI\/testing-procedures-of-sni-iec-66086-12015\/#1_Capacity_Testing\" >1. Capacity Testing<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.dimulti.id\/SNI\/testing-procedures-of-sni-iec-66086-12015\/#2_Voltage_Testing\" >2. Voltage Testing<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.dimulti.id\/SNI\/testing-procedures-of-sni-iec-66086-12015\/#3_Discharge_Characteristics_Testing\" >3. Discharge Characteristics Testing<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.dimulti.id\/SNI\/testing-procedures-of-sni-iec-66086-12015\/#4_Shelf_Life_Testing\" >4. Shelf Life Testing<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.dimulti.id\/SNI\/testing-procedures-of-sni-iec-66086-12015\/#5_Leakage_Testing\" >5. Leakage Testing<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.dimulti.id\/SNI\/testing-procedures-of-sni-iec-66086-12015\/#6_Thermal_Stability_Testing\" >6. Thermal Stability Testing<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.dimulti.id\/SNI\/testing-procedures-of-sni-iec-66086-12015\/#7_Short-Circuit_Testing\" >7. Short-Circuit Testing<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Testing_Procedures_of_SNI_IEC_66086-1_2015\"><\/span>Testing Procedures of SNI IEC 66086-1:2015<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"675\" src=\"https:\/\/www.dimulti.id\/SNI\/wp-content\/uploads\/2024\/08\/Testing-Procedures-of-SNI-IEC-66086-12015-2.jpg\" alt=\"\" class=\"wp-image-1973\" srcset=\"https:\/\/www.dimulti.id\/SNI\/wp-content\/uploads\/2024\/08\/Testing-Procedures-of-SNI-IEC-66086-12015-2.jpg 1200w, https:\/\/www.dimulti.id\/SNI\/wp-content\/uploads\/2024\/08\/Testing-Procedures-of-SNI-IEC-66086-12015-2-300x169.jpg 300w, https:\/\/www.dimulti.id\/SNI\/wp-content\/uploads\/2024\/08\/Testing-Procedures-of-SNI-IEC-66086-12015-2-1024x576.jpg 1024w, https:\/\/www.dimulti.id\/SNI\/wp-content\/uploads\/2024\/08\/Testing-Procedures-of-SNI-IEC-66086-12015-2-768x432.jpg 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<p>There are several testing procedures of SNI IEC 66086-1:2015, these include a capacity testing voltage testing, discharge testing, shelf life testing and leakage testing.<\/p>\n\n\n\n<p>So, without further ado, let\u2019s check the full explanation down below!<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"1_Capacity_Testing\"><\/span>1. Capacity Testing<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>This test is to ensure the battery\u2019s ability to store and deliver electrical energy.<\/p>\n\n\n\n<p>Capacity is measured in milliampere-hours (mAh) or ampere-hours (Ah). The capacity is calculated as the product of the discharge current and the time taken to reach the cutoff voltage.<\/p>\n\n\n\n<p>First, the battery is fully charged or brought to its standard state of charge, then the battery is discharged at a constant current until it reaches its cutoff voltage.<\/p>\n\n\n\n<p>The test ensures that the battery meets its rated specifications and provides adequate power for its intended applications.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"2_Voltage_Testing\"><\/span>2. Voltage Testing<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The next one is voltage testing to verify that the nominal voltage of the battery should maintain under specified every day conditions.<\/p>\n\n\n\n<p>The voltage is measured using a calibrated voltmeter immediately after the battery is brought to its standard state of charge.<\/p>\n\n\n\n<p>This testing is to ensure that the battery maintains its specified voltage, which is crucial for compatibility with devices that rely on precise voltage levels for proper operation.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><em>Also Read: &#8220;<a href=\"https:\/\/www.dimulti.id\/SNI\/types-of-batteries\/\">Types of Batteries<\/a>&#8220;<\/em><\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"3_Discharge_Characteristics_Testing\"><\/span>3. Discharge Characteristics Testing<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The objective of this test is to evaluate how the battery would perform under various discharge conditions.<\/p>\n\n\n\n<p>The batteries are tested at different discharge rates, to monitor its performance across a range of currents.<\/p>\n\n\n\n<p>This is usually conducted by mimicking the everyday condition that the batteries might experience.<\/p>\n\n\n\n<p>Then, the voltage\u2019s behavior is monitored throughout the discharge cycle to evaluate how well it maintains performance under certain loads.<\/p>\n\n\n\n<p>This testing provides insight into how the battery performs in real-world scenarios, where devices may draw varying amounts of current.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"4_Shelf_Life_Testing\"><\/span>4. Shelf Life Testing<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The next testing procedures of SNI IEC 66086-1:2015 is the shelf life testing that is conducted to monitor the battery\u2019s ability to retain its charge over an extended period of time.<\/p>\n\n\n\n<p>The batteries are tested at regular intervals during storage to monitor changes in capacity and performance.<\/p>\n\n\n\n<p>And at the end of the test, the battery\u2019s performance is compared against initial specifications, this is done to determine the battery\u2019s ability to retain its charge.<\/p>\n\n\n\n<p>Overall, the shelf life testing ensures that batteries could maintain their performance over time, even when not in use.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"5_Leakage_Testing\"><\/span>5. Leakage Testing<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>There is also leakage testing, which is to ensure that the battery is designed and constructed to prevent any leakage that might appear.<\/p>\n\n\n\n<p>This test is conducted by applying various conditions such as high temperatures or physical tests that might cause a leakage.<\/p>\n\n\n\n<p>After that, the visual inspection and chemical test are performed to check if there\u2019s any signs of leakage or damage to the batteries.<\/p>\n\n\n\n<p>Also, a performance testing is also performed to evaluate the performance after exposure to leakage conditions.<\/p>\n\n\n\n<p>Leakage testing is crucial for safety, preventing chemical spills that could cause harm or damage to devices.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"6_Thermal_Stability_Testing\"><\/span>6. Thermal Stability Testing<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Another thing to be tested is the batteries thermal stability which the batteries are put under specific high-temperature condition for extended periods.<\/p>\n\n\n\n<p>The battery performance and safety are then monitored throughout the exposure period, then tested for any changes in performance or signs of safety issues after exposure.<\/p>\n\n\n\n<p>Thermal stability testing ensures that the battery can operate safely and effectively in higher temperature environments, which is important for devices exposed to varying thermal conditions.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><em>Also Read: &#8220;<a href=\"https:\/\/www.dimulti.id\/SNI\/the-sni-certification-for-batteries-in-indonesia\/\">The SNI Certification for Batteries in Indonesia<\/a>&#8220;<\/em><\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"7_Short-Circuit_Testing\"><\/span>7. Short-Circuit Testing<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>The last but definitely not least is short-circuit testing, which assesses the battery\u2019s response to a short-circuit condition.<\/p>\n\n\n\n<p>The test is performed by putting the batteries under a controlled&nbsp; short circuit that is created across the battery terminals.<\/p>\n\n\n\n<p>Then, the battery&#8217;s behavior during the short circuit is monitored, including temperature rise and potential for leakage or rupture.&nbsp;<\/p>\n\n\n\n<p>Evaluation for the battery\u2019s performance and safety are also performed after the short-circuit condition is removed.<\/p>\n\n\n\n<p>This test is so important to ensure the battery\u2019s safety mechanisms function correctly and that the battery does not pose a hazard under short-circuit conditions.<\/p>\n\n\n\n<p>There you have it! The testing procedures of SNI IEC 66086-1:2015!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Testing Procedures of SNI IEC 66086-1:2015 &#8211; There are several things that must be done<\/p>\n","protected":false},"author":4,"featured_media":1972,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[215,216],"tags":[163,8],"class_list":["post-1971","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-batteries","category-regulations","tag-batteries","tag-sni"],"_links":{"self":[{"href":"https:\/\/www.dimulti.id\/SNI\/wp-json\/wp\/v2\/posts\/1971","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dimulti.id\/SNI\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dimulti.id\/SNI\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dimulti.id\/SNI\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dimulti.id\/SNI\/wp-json\/wp\/v2\/comments?post=1971"}],"version-history":[{"count":0,"href":"https:\/\/www.dimulti.id\/SNI\/wp-json\/wp\/v2\/posts\/1971\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dimulti.id\/SNI\/wp-json\/wp\/v2\/media\/1972"}],"wp:attachment":[{"href":"https:\/\/www.dimulti.id\/SNI\/wp-json\/wp\/v2\/media?parent=1971"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dimulti.id\/SNI\/wp-json\/wp\/v2\/categories?post=1971"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dimulti.id\/SNI\/wp-json\/wp\/v2\/tags?post=1971"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}